Rheem RTG 7.0 GPM Propane Outdoor Specifications

Researched from the DOE test procedures, NFPA 54 and NEC code tables, and manufacturer specifications. Updated .

Quick answer

The Rheem RTG 7.0 GPM Propane Outdoor is a whole house gas tankless rated at 160,000 BTU per hour. Its listing states a maximum flow of 7 gallons per minute, but the listing does not state the temperature rise that figure is measured at, so it is a model identifier rather than a specification.

This page collects what is actually published about the Rheem RTG 7.0 GPM Propane Outdoor and shows what those figures produce, computed rather than transcribed. Anything the listing does not publish is not filled in with an estimate.

One caution about the flow figure. The listing title states 7 gallons per minute with no temperature rise attached. Flow and rise trade against each other directly, so a flow figure without a rise is not a specification. The table below shows what the published input rating actually produces across the range.

Published specifications

Everything here is taken from the listing or the manufacturer, and nothing is inferred.

Rheem RTG 7.0 GPM Propane Outdoor published figures
SpecificationValue
FuelPropane
Btu Input160000
Max Flow Gpm7
CondensingNo
MountingOutdoor

Published standard Source: Manufacturer listing data. A specification not listed here is one this listing does not publish. Check the installation manual for the full data plate.

Flow across the temperature rise range

Computed from the published input rating with the energy relation, so these figures cannot disagree with the calculators on this site.

Flow at each temperature rise from a 160,000 BTU input
Temperature riseFlowInlet needed for a 120 F outlet
35 F7.5 GPM85 F
45 F5.8 GPM75 F
60 F4.4 GPM60 F
70 F3.8 GPM50 F
80 F3.3 GPM40 F
90 F2.9 GPM30 F

Published standard Source: Energy relation applied to the published 160,000 BTU input at an assumed 82 percent thermal efficiency. These are computed from the published input rating, not taken from the manufacturer curve. The installation manual curve is the authority and accounts for modulation.

What gas line it needs

At 160,000 BTU per hour this draws about 155 cubic feet of natural gas per hour. Over a 40 foot run the NFPA 54 low pressure table calls for 1 inch Schedule 40 pipe.

Check your own run length on the gas line page for the nearest input worked through in full. Gas line upsizing is routinely the largest single line in a tankless quote and the one most often missed from an estimate.

How it sits against the rest of its category

Other whole house gas tankless in this catalog: Rheem RTGH 6.8 GPM Natural Gas Indoor, Rheem RTGH 8.4 GPM Natural Gas Indoor, Rheem RTGH 9.0 GPM Natural Gas Indoor, Rinnai V53DeN Natural Gas.

Compare them on input rating and on the figures the manufacturer actually publishes rather than on the headline number in the listing title, which in this category is frequently a maximum measured under conditions the listing never states.

Other whole house gas tankless

Frequently asked questions

What are the specifications of the Rheem RTG 7.0 GPM Propane Outdoor?
The listing publishes fuel, btu input, max flow gpm, condensing and related figures, shown in full in the table on this page. Anything not shown is something the listing does not publish, and this page does not estimate it.
Does the Rheem RTG 7.0 GPM Propane Outdoor really deliver 7 gallons per minute?
At some temperature rise, yes, and the listing does not say which one. Flow and rise trade against each other directly: the same unit that makes a given flow at a 35 F rise makes roughly half of it at a 70 F rise. Take the flow curve from the installation manual and read it at your own inlet temperature rather than trusting the headline figure.
What gas line does the Rheem RTG 7.0 GPM Propane Outdoor need?
About 155 cubic feet per hour, which over a 40 foot run calls for 1 inch Schedule 40 pipe under the NFPA 54 low pressure table. Fittings add equivalent length this does not account for, and other gas appliances share the meter, so a gas fitter sizes the whole system.
Is this page based on hands-on testing?
No, and we never claim otherwise. Everything here is compiled from the manufacturer listing, published specifications and the energy relations that turn those specifications into flow and recovery figures. We do not test products in person. Where a figure is not published, this page says so rather than estimating it.
Are the prices on this page current?
They come from verified catalog data at the time the page was built, and prices in this category move often. Treat any price shown as a guide and check the listing itself before deciding. Availability moves even faster than price does on water heater accessories in particular.

Gas and flue work belongs to a licensed plumber or gas fitter. An undersized gas line starves a burner, and a starved burner produces carbon monoxide. Backdrafting on an atmospheric vent is real, it is invisible, and it kills. Nothing on this page is a substitute for the sizing done by the person who signs the permit, and a working carbon monoxide alarm belongs on every floor of a house with a gas appliance.